MIL-DTL-81248C
Table II. Conformance inspection.
Inspection
Requirement
Test Method
Dimensions
3.2.1.1
Industry Standards
Uranine coating
3.2.2
4.5.1
Heat-seal
3.3
4.5.2
Color
3.4
4.5.3
Contamination
3.5
4.5.4
Filterability/Flow
3.6
4.5.5
Workmanship
3.7
Visual examination
Marking
3.7 and 3.7.1
Visual examination
4.3.1 Conformance samples. Unless otherwise specified, conformance samples for the
inspections shall be selected at random in accordance with MIL-STD-1916 and table III below.
TABLE III. Conformance sampling.
Inspection 1/
Verification
Sampling Unit
Level
Dimensions
IV
Detector pad before packaging
Uranine coating
IV
Detector pad before packaging
Heat-seal
IV
Unit pack
Color
IV
Detector pad before packaging
Contamination
IV
Immediate container
Filterability/Flow
IV
Immediate container
Workmanship
II
Detector pad before packaging
Marking
I
Unit pack.
1/ The lot size (see 6.5.1) shall be the number of unit packs for all inspections.
4.4 Inspection conditions. Unless otherwise specified in the detailed test methods specified
herein, the physical tests contained in this specification shall be performed with an atmosphere
having a relative humidity of 50 ± 10 percent and a temperature ranging from 18 to 27 °C (65 to
80 °F).
4.5 Examinations and tests.
4.5.1 Uranine content.
4.5.1.1 Apparatus. The apparatus shall consist of a fluorometer or spectrophotometer with
fluorometric attachment with a sensitivity capable of detecting 0.02 micrograms of uranine per
milliliter of water and standard laboratory glass volumetric flasks (1000 mL and 100 mL
capacity).