MIL-DTL-81248C
filtered through the detector pad in 37.5 to 50 seconds (indicating a fuel flow rate of 600 to 800
mL/min).
3.7 Marking. Each unit pack shall be marked in accordance with MIL-STD-129.
3.7.1 Additional marking. Each unit pack shall be marked with the following:
a.
Lot number
b.
Date of manufacture
c.
CAUTION: The enclosed detector pad is highly sensitive to water and water vapor.
Do not open envelope until seconds prior to use. Remove and handle the enclosed
detector pad with tweezers. Do not touch with fingers.
3.8 Workmanship. When visually examined, the detector pad shall be evenly coated and
free from foreign matter, holes, tears, cuts, creases, wrinkles, printing, and other imperfections
that render the pad unusable for its intended use.
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified
as follows:
a. First article inspection (see 4.2)
b. Conformance inspection (see 4.3)
4.2 First article inspection. First article inspection shall be performed on one complete
package containing a free water detector pad when a first article sample is specified (see 3.1).
The sample shall be representative of the production item and shall be taken from a production
lot (see 6.5.1). First article inspection shall consist of all tests and examination specified in this
specification.
4.3 Conformance inspection. Conformance inspection shall consist of the examinations and
tests specified in table II for each production run. A sample (see 4.3.1) that does not conform to
all the applicable conformance requirements shall be cause for rejection.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business